Material

Start & Stop Valve

Description

These are typically two solenoid coil wounded in a bobbin at the different winding directions of one after another. It has two power sources, one is for the open coil & another one is for the close coil. If the open coil is energized, the valve gets open, and it remains open even the electrical supply is removed. This because of the latching effect of the magnets. The valve can get closed while giving the electrical supply to the closed coil. The operating pressure may vary since these are customized ones.

Specifications

Type

3 Way Solenoid Operated Latch Valve

Fluid Media

GN2 & GH₂ at ambient

Working Pressure

25 bar(a) max

Time for Opening / Closing

10 Seconds

Operating Voltage

28 VDC

Weight

0.6 kg

EV-Spec

Operating Temperature

-40 to 70°C

Maximum Continuous Operating Time

30Minutes

Vibration Level

30-g-random 20-2000 Hz

Shock Level

50-g, 100 m/sec

Operationa

Intermittent

Operational Life

100hrs

Operating Altitude

52k